Window Wells: Section: R31 0.2
The horizontal dimensions of a window well shall allow
the emergency escape and rescue opening to be fully
opened. The horizontal dimensions of the window well
shall provide a minimum net clear area of (9) square
feet with a minimum horizontal projection and width
of 36 inches. Exception : The ladder or steps required
by section R31 0.2.1 shall be permitted to encroach
a maximum of 6 inches into the required dimensions of
the window well.
Ladder and Steps: Section: R310.2.1
Window wells with a vertical depth greater than 44 inches
below adjacent ground level shall be equipped with a
permanently affixed ladder or steps useable with the
window in the fully open position. Ladders or rungs
shall have an inside width of at least 12 inches, shall
project at least 3 inches from the wall and shall be
spaced not more than 18 inches on center vertically
for the height of the window well.
Bars, Grills, Covers and Screens: Section: R31 0.3
Placed over emergency escape and rescue opening or window
wells that serve such openings shall be releasable or
removable from the inside without the use of a key,
tool or special knowledge.